全文获取类型
收费全文 | 1679篇 |
免费 | 196篇 |
国内免费 | 113篇 |
专业分类
测绘学 | 270篇 |
大气科学 | 315篇 |
地球物理 | 473篇 |
地质学 | 399篇 |
海洋学 | 8篇 |
综合类 | 77篇 |
自然地理 | 446篇 |
出版年
2024年 | 1篇 |
2023年 | 11篇 |
2022年 | 39篇 |
2021年 | 30篇 |
2020年 | 61篇 |
2019年 | 82篇 |
2018年 | 65篇 |
2017年 | 118篇 |
2016年 | 81篇 |
2015年 | 96篇 |
2014年 | 90篇 |
2013年 | 124篇 |
2012年 | 48篇 |
2011年 | 94篇 |
2010年 | 66篇 |
2009年 | 108篇 |
2008年 | 121篇 |
2007年 | 115篇 |
2006年 | 115篇 |
2005年 | 74篇 |
2004年 | 68篇 |
2003年 | 62篇 |
2002年 | 52篇 |
2001年 | 53篇 |
2000年 | 26篇 |
1999年 | 34篇 |
1998年 | 34篇 |
1997年 | 17篇 |
1996年 | 13篇 |
1995年 | 8篇 |
1994年 | 7篇 |
1993年 | 22篇 |
1992年 | 10篇 |
1991年 | 13篇 |
1990年 | 10篇 |
1989年 | 4篇 |
1988年 | 12篇 |
1987年 | 2篇 |
1984年 | 1篇 |
1954年 | 1篇 |
排序方式: 共有1988条查询结果,搜索用时 46 毫秒
101.
The dynamic identification of a historical masonry palace located in Benevento (Italy) has been carried out. The case study is representative of many buildings located in historic Italian centres. Since the building has been instrumented by the Department of Civil Protection with a permanent dynamic monitoring system, some of the recorded data, acquired in various operating conditions have been analysed with basic instruments of the Operational Modal Analysis in order to identify the main eingenfrequencies and vibration modes of the structure. The experimental results have been compared to the numerical outcomes provided by a detailed three-dimensional Finite Element (FE) model of the building where Soil–Structure Interaction (SSI) has been taken into account. The comparison of experimental vs. numerical frequencies and vibration modes of the palace evidenced the role exerted by the subsoil on the dynamic response of the building. 相似文献
102.
A framework for the seismic assessment of existing masonry buildings accounting for different sources of uncertainty 下载免费PDF全文
The current formulation of Eurocode 8 Part 3 and the Italian building code for the seismic assessment of existing buildings accounts for epistemic (knowledge‐based) uncertainties by means of the identification of knowledge levels with associated values of the so‐called confidence factors, applied only as a reduction of material strengths. This formulation does not always produce consistent results and it does not explicitly account for other sources of uncertainty. The paper proposes a probabilistic methodology for the quantification of appropriately defined factors, allowing consideration of the different sources of uncertainty involved in the seismic assessment of masonry buildings by means of nonlinear static analyses. This simple approach, also including an alternative formulation of the confidence factors related with material properties, allows to obtain results which are consistent with the acquired level of knowledge and correctly account for the different sources of uncertainty without requiring to carry out any stochastic nonlinear analysis. Copyright © 2013 John Wiley & Sons, Ltd. 相似文献
103.
A 54‐story steel, perimeter‐frame building in downtown Los Angeles, California, is identified by a wave method using records of the Northridge earthquake of 1994 (ML = 6.4, R = 32 km). The building is represented as a layered shear beam and a torsional shaft, characterized by the corresponding velocities of vertically propagating waves through the structure. The previously introduced waveform inversion algorithm is applied, which fits in the least squares sense pulses in low‐pass filtered impulse response functions computed at different stories. This paper demonstrates that layered shear beam and torsional shaft models are valid for this building, within bands that include the first five modes of vibration for each of the North–South (NS), East–West (EW), and torsional responses (0–1.7 Hz for NS and EW, and 0–3.5 Hz for the torsional response). The observed pulse travel time from ground floor to penthouse level is τ ≈1.5 s for NS and EW and τ ≈ 0.9 s for the torsional responses. The identified equivalent uniform shear beam wave velocities are βeq ≈ 140 m/s for NS and EW responses, and 260 m/s for torsion, and the apparent Q ≈ 25 for the NS and torsional, and ≈14 for the EW response. Across the layers, the wave velocity varied 90–170 m/s for the NS, 80–180 m/s for the EW, and 170–350 m/s for the torsional responses. The identification method is intended for use in structural health monitoring. Copyright © 2013 John Wiley & Sons, Ltd. 相似文献
104.
Pawe? Koperski 《Limnologica》2010,40(3):233-240
Reduced biological diversity in freshwater habitats situated in urban areas has been discussed in numerous studies. Certain municipal areas, however, can help save animal diversity of freshwater invertebrates. In the present study animals were collected or observed alive in 13 freshwater environments localized in Warsaw - the second largest city of Central Europe - in a densely populated, urban building complex close to the city, and also in suburban areas. Leech assemblages in all the environments under observation were numerically dominated by a few common species, but on the whole 19 species were collected or observed. The populations of six rare leech species inhabit both flowing and standing waters in Warsaw. Five of these species are on the Polish Red List of Species and one is strictly protected. The shallow Lake Powsinkowskie is the richest freshwater environment in the studied area in terms of species richness and rarity and also one of the richest lakes in Poland. Taxonomic diversity in the environments under study seems not to be directly related to the size of the water body or the level of degradation but rather to the habitat complexity, especially the diversity of the bottom in littoral zone. Certain freshwater habitats located inside this great urban complex still create good conditions for rare, highly specialized species. 相似文献
105.
P. Kamatchi J. Rajasankar Nagesh R. Iyer N. Lakshmanan G.V. Ramana A.K. Nagpal 《Soil Dynamics and Earthquake Engineering》2010
Towards formulating guidelines for performance evaluation of buildings to site-specific earthquakes, studies are reported in literature on the effect of various critical parameters. No study is, however, reported on the effect of depth of soil stratum. In this paper, a methodology is proposed and applied for performance evaluation of buildings for site-specific earthquakes including depth of soil stratum as a parameter. The methodology integrates independent procedures meant for performance evaluation of buildings and site-specific seismic analysis. Application of the proposed methodology enables to determine performance point of a building in terms of inelastic displacement and base shear. Numerical application of the methodology is demonstrated using the particulars of Delhi region. Two typical RC buildings (B1 and B2) with significantly different inelastic behaviour, assumed to be located on soil depths ranging from 10 to 200 m are chosen for the application study. Capacity spectra of the buildings are generated from nonlinear static analysis. Studies indicate that for building B1, with elasto-plastic behaviour, the depth of soil stratum strongly influences demand on inelastic displacement compared to that on inelastic base shear. For building B2, with continuously varying inelastic behaviour, the depth of soil stratum is observed to have significant influence on both the inelastic base shear as well as inelastic displacement. Responses of the buildings are compared with that obtained based on design spectrum of Indian seismic code. For both the cases, inelastic displacements as well as inelastic base shears are underestimated by Indian seismic code for certain depths of soil stratum. Proposed methodology enables the calculation of realistic values of inelastic base shear and corresponding displacement of a building for site-specific earthquakes by considering the actual characteristics of soil stratum. 相似文献
106.
高层钢结构地震失效模式控制的失效路径修正法 总被引:1,自引:0,他引:1
本文主要研究高层钢框架结构的地震失效模式及其控制方法。首先,给出了高层钢结构的地震失效模式的分析方法;其次,提出了根据结构的失效路径来加强构件对高层钢结构的地震失效模式进行控制的方法;然后,提出了结构整体抗震能力的分析方法以及分别相应于设计能力和屈服能力的能力储备分析方法;最后,通过对一座15层的钢框架结构进行典型地震动下的极限时程分析和极限pushover分析,得到高层钢框架结构的失效模式和整体抗震能力以及相应于最弱失效模式的能力储备,并验证了本文中地震失效模式控制方法的有效性。本文的研究表明,高层钢结构的地震失效模式控制可以采用结构失效路径修正(薄弱构件加强)来实现。 相似文献
107.
总结了2008年汶川8.0级地震在甘肃陇南地区造成的农村房屋和城镇房屋的典型震害及其原因。考察发现,由于农村房屋一般未经抗震设防设计,在本次地震中即使在低烈度地区仍然震害严重;而城镇房屋震害较轻,一般均表现出良好的抗震性能,严重破坏的大多是一些施工质量差,缺乏良好的抗震概念设计以及改建时未考虑抗震设计的建筑。建筑震害调查的几个地区设防烈度均为Ⅷ度,实际烈度为Ⅵ~Ⅸ度,因此这些地区的房屋震害情况刚好能反映这些地区房屋抵抗小震、中震及大震的能力。结果表明,严格按照抗震规范设计、并保证施工质量的建筑基本都能达到三水准设防目标。最后本文对灾后重建和抗震设防提出了建议。 相似文献
108.
109.
对杭州城区四个不同功能区块土壤进行了系统的环境磁学测定,结果表明城市土壤的磁化率平均值为128×10-8m3·kg-1,频率磁化率平均值3.6%(样品数=182),城市土壤呈现明显的磁性增强. 城市土壤的磁化率与频率磁化率呈极显著指数负相关,表明城市土壤磁性增强明显区别于自然成土过程引起的以超顺磁性(SP)颗粒为主的表土磁性增强机理. 统计分析表明,城市土壤磁化率与软剩磁和饱和等温剩磁(SIRM)呈显著直线正相关,说明亚铁磁性矿物是城市土壤剩余磁性的主要载体. 综合等温剩磁获得曲线、热磁曲线、磁滞回线等岩石磁学测定和SEM/EDX分析,城市土壤的磁性矿物以磁铁矿和赤铁矿为主,磁性矿物以假单畴-多畴(PSD-MD)颗粒存在,粒度明显大于成土过程形成的磁性颗粒,这些磁性颗粒主要来自燃料燃烧、汽车尾气等环境污染物. 因此,城市土壤磁测可作为城市土壤污染监测、污染空间分布和污染物来源判断的新手段. 相似文献
110.